0225P2-2-030K [NUVOTEM TALEMA]

225VA Encapsulated Style, with Leads.;
0225P2-2-030K
型号: 0225P2-2-030K
厂家: NUVOTEM TALEMA    NUVOTEM TALEMA
描述:

225VA Encapsulated Style, with Leads.

文件: 总1页 (文件大小:252K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
nuvotem  
A Talema Group Company  
Toroidal Transformer Data Sheet  
225VA Encapsulated Style, with Leads.  
Dual Primaries, Dual Secondaries  
High quality encapsulated toroidal transformers with dual 115V/50-60Hz primary windings.  
Twin secondary windings may be connected in series or parallel, or used independently  
Primary 2x115V @ 50-60Hz  
Suitable for Series/Parallel connection  
Secondary: 2 x Vsec @ 112.5VA Each  
Suitable for Series/Parallel connection  
Nuvotem  
Part Number  
Full Load Rated Current  
No Load  
Vsec [V]  
2 x 13.14  
2 x 16.32  
2 x 19.71  
2 x 27.42  
2 x 32.86  
DC Resistance  
[Ohms] @ 25'C  
2 x 0.0574  
DEKRA  
Vsec [V]  
2 x 12  
2 x 15  
2 x 18  
2 x 25  
2 x 30  
per Sec [A]  
Certificate  
2161054.01  
2161054.01  
2161054.01  
2161054.02  
2161054.02  
0225P2-2-012K  
0225P2-2-015K  
0225P2-2-018K  
0225P2-2-025K  
0225P2-2-030K  
9.375  
7.500  
6.250  
4.500  
2 x 0.0901  
2 x 0.1245  
2 x 0.2491  
2 x 0.3709  
3.750  
Primary Winding  
Input Voltage Range :  
Series: 207V253V (230V±10%) @ 50/60Hz  
Parallel: 103.5V126.5V (115V±10%) @ 50/60Hz  
DC Resistance @ 25'C = Approx 3.7 Ohms each  
Losses  
Iron Losses  
1.19 Watts approx  
Copper Losses 25.0 Watts approx  
Temperature Class  
Winding Wire (Primary & Secondary)  
Insulation between input and output  
Connection lead insulation  
Class H (180'C)  
Class B (130'C)  
Class A (105'C)  
Standards  
Approved to UL506 & UL5085 : File E215495  
Approved to EN61558 : DEKRA Certificates 2161054.01 and 2161054.02 (see table above)  
Conforms to EN60065, VDE0550, BS415.  
Physical Data  
Encapsulated in Black Cylindrical Case, with 6.1mm centre hole.  
Case Diameter  
Case Height  
125.8mm  
52.4mm  
Approximate Weight  
2.10 Kg  
Terminations  
Primary  
Solid copper conductors (extension of winding wire),  
insulated over their entire length with 105°C PVC tubing.  
Double-insulated over entire length with 105°C PVC tubing.  
150mm Long, 10mm tinned ends.  
Secondary  
Solid copper conductors (extension of winding wire),  
insulated over their entire length with 105°C PVC tubing.  
150mm Long, 10mm tinned ends.  
Nuvotem Talema, Units W-X, Gweedore Business Park, Derrybeg, Co. Donegal, Ireland, F92 AT8F  
Tel:+353 7495 48666 Fax:+353 7495 48139 Email: info@nuvotem.com www.nuvotem.com  

相关型号:

0225P2-2-055

225VA Open Style, with Leads
NUVOTEM TALEM

022604

Circular Connector, 4 Contact(s), Glass Filled PEI, Male, Solder Terminal, Plug
LUMBERG

022607

Circular Connector, 7 Contact(s), Glass Filled PEI, Male, Solder Terminal, Plug
LUMBERG

022608

Circular Connector, 8 Contact(s), Glass Filled PEI, Male, Solder Terminal, Plug
LUMBERG

022611-000

RAYCHEM Tubing Products
MACOM

022622

Circular Connector, 22 Contact(s), Glass Filled PEI, Male, Solder Terminal, Plug
LUMBERG

022624

Circular Connector, 24 Contact(s), Glass Filled PEI, Male, Solder Terminal, Plug
LUMBERG

022627

Circular Connector, 27 Contact(s), Glass Filled PEI, Male, Solder Terminal, Plug
LUMBERG

0226360000

SAK-series
WEIDMULLER

0226460000

SAK-series
WEIDMULLER

0229.250

Electric Fuse, Slow Blow, 0.25A, 250VAC, 35A (IR), Inline/holder
LITTELFUSE

0229.250HXP

229/230 Series Lead-Free 2AG, Slo-Blo® Fuse and Indicating Slo-Blo® Fuse
LITTELFUSE